Digital Clamp Meter CMP-402

The Sonel CMP-402 Digital Clamp Meter measures AC current, AC and DC voltage and more.

Index: WMGBCMP402

Skicka förfrågan

Digital Clamp Meter CMP-402

The Sonel CMP-402 Digital Clamp Meter measures AC current, AC and DC voltage and more.

Index: WMGBCMP402

Skicka förfrågan

Beskrivning

The Sonel CMP-402 measures AC current, AC and DC voltage and more. The meter provides precise measurements downstream of frequency converters. The device is versatile due to many measurement options. Darkness in the workplace is not a problem thanks to the built-in flashlight.

Modern clamp

The innovative shape means easier access in hard to reach and tight places. The clamp edging is equipped with a contactless voltage indicator sensor.

Visibility in any conditions

Darkness in the workplace is not a problem thanks to the built-in flashlight.

Multifunctional

The device is versatile due to many measurement options. In addition to the basic measurements, the instrument has special functions, including inrush current (INRUSH), max / min peak values (Peak MAX/Peak MIN), relative value (REL).

Robust design

With the help of the latest technologies, a compact instrument for working in the toughest conditions has been created. The rubber housing protects the device against accidental damage.

Measurement of converters

The meter provides precise measurements downstream of frequency converters thanks to the VFD function.

Measurement functions Range Resolution Accuracy
AC current up to 400.0 A from 0.01 A from ±(2.0% m.v. + 8 digits)
AC and VFD voltage up to 1000 V from 0.001 V from ±(1.2% m.v. + 5 digits)
DC voltage up to 1000 V from 0.001 V from ±(1.0% m.v. + 3 digits)
Resistance up to 40.00 MΩ from 0.1 Ω from ±(1.0% m.v. + 4 digits)
Frequency
current up to 999.9 Hz from 0.01 Hz ±(1.0% m.v. + 5 digits)
voltage up to 99.99 kHz from 0.01 Hz ±(1.0% m.v. + 5 digits)
Capacitance up to 99.99 mF from 0.001 nF from ±(3.0% m.v. + 5 digits)
Duty cycle (%) 20.0…80.0% 0.1% ±(1.2% m.v. + 10 digits)
Temperature measurement -20.0…+1000ºC
-4.0…+1832ºF
0.1ºC
0.1ºF
±(3% m.v. + 3ºC)
±(3% m.v. + 5ºF)
Continuity / Diode test ✓ / ✓

m.v. = measured value

 

Basic features:

  • Counting: 4.000 digits
  • HOLD
  • Automatic range selection

Advanced features:

  • Current and voltage measurements downstream the inverter, frequency converter or in the VFD system
  • Inrush current
  • Non-contact voltage detector
  • Peak MIN / Peak MAX
  • Relative measurement REL
  • TRMS measurement

Other features​​​​​​​​​​​​​​:

  • Auto-off
  • Empty battery indication
  • Integrated flashlight
  • Beeper
  • Display:
    • Type: segment-based LCD, 4 digits
    • Display backlight: manual

Data sheet

Beskrivning

The Sonel CMP-402 measures AC current, AC and DC voltage and more. The meter provides precise measurements downstream of frequency converters. The device is versatile due to many measurement options. Darkness in the workplace is not a problem thanks to the built-in flashlight.

Modern clamp

The innovative shape means easier access in hard to reach and tight places. The clamp edging is equipped with a contactless voltage indicator sensor.

Visibility in any conditions

Darkness in the workplace is not a problem thanks to the built-in flashlight.

Multifunctional

The device is versatile due to many measurement options. In addition to the basic measurements, the instrument has special functions, including inrush current (INRUSH), max / min peak values (Peak MAX/Peak MIN), relative value (REL).

Robust design

With the help of the latest technologies, a compact instrument for working in the toughest conditions has been created. The rubber housing protects the device against accidental damage.

Measurement of converters

The meter provides precise measurements downstream of frequency converters thanks to the VFD function.

Measurement functions Range Resolution Accuracy
AC current up to 400.0 A from 0.01 A from ±(2.0% m.v. + 8 digits)
AC and VFD voltage up to 1000 V from 0.001 V from ±(1.2% m.v. + 5 digits)
DC voltage up to 1000 V from 0.001 V from ±(1.0% m.v. + 3 digits)
Resistance up to 40.00 MΩ from 0.1 Ω from ±(1.0% m.v. + 4 digits)
Frequency
current up to 999.9 Hz from 0.01 Hz ±(1.0% m.v. + 5 digits)
voltage up to 99.99 kHz from 0.01 Hz ±(1.0% m.v. + 5 digits)
Capacitance up to 99.99 mF from 0.001 nF from ±(3.0% m.v. + 5 digits)
Duty cycle (%) 20.0…80.0% 0.1% ±(1.2% m.v. + 10 digits)
Temperature measurement -20.0…+1000ºC
-4.0…+1832ºF
0.1ºC
0.1ºF
±(3% m.v. + 3ºC)
±(3% m.v. + 5ºF)
Continuity / Diode test ✓ / ✓

m.v. = measured value

 

Basic features:

  • Counting: 4.000 digits
  • HOLD
  • Automatic range selection

Advanced features:

  • Current and voltage measurements downstream the inverter, frequency converter or in the VFD system
  • Inrush current
  • Non-contact voltage detector
  • Peak MIN / Peak MAX
  • Relative measurement REL
  • TRMS measurement

Other features​​​​​​​​​​​​​​:

  • Auto-off
  • Empty battery indication
  • Integrated flashlight
  • Beeper
  • Display:
    • Type: segment-based LCD, 4 digits
    • Display backlight: manual

Data sheet