Digital Clamp meter CMP-1010

The Sonel CMP-1010 Clamp Meter measures AC and DC current, AC and DC voltage and more.

Index: WMGBCMP1010

2380,00 kr

Skicka förfrågan

Digital Clamp meter CMP-1010

The Sonel CMP-1010 Clamp Meter measures AC and DC current, AC and DC voltage and more.

Index: WMGBCMP1010

2380,00 kr

Skicka förfrågan

Beskrivning

The Sonel CMP-1010 measures AC and DC current, AC and DC voltage and more. The meter provides precise measurements downstream of frequency converters. The device is versatile due to many measurement options, including low-impedance voltage measurement (Low Z). Darkness in the workplace is not a problem thanks to the built-in flashlight.

Modern clamp

The innovative shape means easier access in hard to reach and tight places. The clamp edging is equipped with a contactless voltage indicator sensor.

Visibility in any conditions

Darkness in the workplace is not a problem thanks to the built-in flashlight.

Multifunctional

The device is versatile due to many measurement options. In addition to the basic measurements, the instrument has special functions, including inrush current (INRUSH), max / min peak values (Peak MAX/Peak MIN), relative value (REL), low-impedance voltage measurement (Low Z).

Robust design

With the help of the latest technologies, a compact instrument for working in the toughest conditions has been created. The rubber housing protects the device against accidental damage.

Measurement of converters

The meter provides precise measurements downstream of frequency converters thanks to the VFD function.

  • Technical specifications

    Measurement functions Range Resolution Accuracy
    AC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 8 digits)
    DC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 5 digits)
    AC voltage up to 1000 V from 0.001 V ±(1.5% m.v. + 5 digits)
    DC voltage up to 1000 V from 0.1 mV from ±(0.5% m.v. + 5 digits)
    Low Z up to 300.0 V from 0.001 V ±(3.0% m.v. + 40 digits)
    Resistance up to 60.00 MΩ from 0.1 Ω from ±(1.0% m.v. + 4 digits)
    Frequency up to 99.99 kHz from 0.001 Hz ±(1.2% m.v. + 5 digits)
    Capacitance up to 100.0 mF from 0.01 nF from ±(3.0% m.v. + 5 digits)
    Duty cycle (%) 10.0…90.0% 0.1% ±(1.2% m.v. + 2 digits)
    Temperature measurement -20.0…+1000ºC
    -4.0…+1832ºF
    0.1ºC
    0.1ºF
    ±(3% m.v. + 5ºC)
    ±(3% m.v. + 9ºF)
    Continuity / Diode test ✓ / ✓

    m.v. – measured value

     

    Basic features:

    • Counting: 6.000 digits
    • HOLD
    • Automatic range selection

    Advanced features:

    • Current and voltage measurements downstream the inverter, frequency converter or in the VFD system
    • Inrush current
    • Non-contact voltage detector
    • Peak MIN / Peak MAX
    • Relative measurement REL
    • TRMS measurement

    Other features​​​​​​​​​​​​​​:

    • Auto-off
    • Empty battery indication
    • Integrated flashlight
    • Beeper
    • Display:
      • Type: segment-based LCD, 4 digits
      • Display backlight: manual

     

Data sheet

 

Beskrivning

The Sonel CMP-1010 measures AC and DC current, AC and DC voltage and more. The meter provides precise measurements downstream of frequency converters. The device is versatile due to many measurement options, including low-impedance voltage measurement (Low Z). Darkness in the workplace is not a problem thanks to the built-in flashlight.

Modern clamp

The innovative shape means easier access in hard to reach and tight places. The clamp edging is equipped with a contactless voltage indicator sensor.

Visibility in any conditions

Darkness in the workplace is not a problem thanks to the built-in flashlight.

Multifunctional

The device is versatile due to many measurement options. In addition to the basic measurements, the instrument has special functions, including inrush current (INRUSH), max / min peak values (Peak MAX/Peak MIN), relative value (REL), low-impedance voltage measurement (Low Z).

Robust design

With the help of the latest technologies, a compact instrument for working in the toughest conditions has been created. The rubber housing protects the device against accidental damage.

Measurement of converters

The meter provides precise measurements downstream of frequency converters thanks to the VFD function.

  • Technical specifications

    Measurement functions Range Resolution Accuracy
    AC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 8 digits)
    DC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 5 digits)
    AC voltage up to 1000 V from 0.001 V ±(1.5% m.v. + 5 digits)
    DC voltage up to 1000 V from 0.1 mV from ±(0.5% m.v. + 5 digits)
    Low Z up to 300.0 V from 0.001 V ±(3.0% m.v. + 40 digits)
    Resistance up to 60.00 MΩ from 0.1 Ω from ±(1.0% m.v. + 4 digits)
    Frequency up to 99.99 kHz from 0.001 Hz ±(1.2% m.v. + 5 digits)
    Capacitance up to 100.0 mF from 0.01 nF from ±(3.0% m.v. + 5 digits)
    Duty cycle (%) 10.0…90.0% 0.1% ±(1.2% m.v. + 2 digits)
    Temperature measurement -20.0…+1000ºC
    -4.0…+1832ºF
    0.1ºC
    0.1ºF
    ±(3% m.v. + 5ºC)
    ±(3% m.v. + 9ºF)
    Continuity / Diode test ✓ / ✓

    m.v. – measured value

     

    Basic features:

    • Counting: 6.000 digits
    • HOLD
    • Automatic range selection

    Advanced features:

    • Current and voltage measurements downstream the inverter, frequency converter or in the VFD system
    • Inrush current
    • Non-contact voltage detector
    • Peak MIN / Peak MAX
    • Relative measurement REL
    • TRMS measurement

    Other features​​​​​​​​​​​​​​:

    • Auto-off
    • Empty battery indication
    • Integrated flashlight
    • Beeper
    • Display:
      • Type: segment-based LCD, 4 digits
      • Display backlight: manual

     

Data sheet