{"id":5458,"date":"2022-02-25T14:49:06","date_gmt":"2022-02-25T13:49:06","guid":{"rendered":"http:\/\/en.testnordic.com\/?post_type=product&#038;p=5458"},"modified":"2022-04-13T16:25:31","modified_gmt":"2022-04-13T14:25:31","slug":"473-dew-point-mirror","status":"publish","type":"product","link":"https:\/\/testnordic.se\/en\/product\/473-dew-point-mirror\/","title":{"rendered":"473 Dew Point Mirror"},"content":{"rendered":"<p>The 473 Dew point Mirror features cable mounted dew point measuring heads that allow the user to measure directly within the application environment and includes a temperature probe as standard. Using both measured variables, the 473 is able to calculate, display and output relative humidity. As an option, the 473 can be specified with a barometric pressure sensor. Three different measuring heads with 2 m connecting cables are available (lengths up to 10 m can be provided on some versions on request).<\/p>\n<p>All 473 instruments are delivered as complete measurement sets that include:<\/p>\n<ul>\n<li>473 display instrument<\/li>\n<li>Measuring head<\/li>\n<li>Measuring head cable<\/li>\n<li>Pt-100 temperature probe and cables<\/li>\n<li>Factory calibration certificate*<\/li>\n<li>IP65 transport case<\/li>\n<\/ul>\n<p>In combination with the T12 multichannel thermometer, the 473 is particularly well suited to climatic chamber validation projects.<\/p>\n<p>* For a small additional cost, the factory calibration can be upgraded to ISO17025 accredited calibration<\/p>\n<section id=\"Features-1\"><strong>Features<\/strong><\/p>\n<div>\n<ul>\n<li>Highly precise chilled mirror dew point technology<\/li>\n<li>Cable mounted dew point and temperature measurement<\/li>\n<li>Aspirated and direct insertion measuring heads<\/li>\n<li>Barometric pressure measurement options<\/li>\n<li>Intuitive color touch screen user interface<\/li>\n<li>User verifiable calibration<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section id=\"Key Specifications-2\"><strong>Key Specifications<\/strong><\/p>\n<div>\n<ul>\n<li>Frost\/dew point range: -30 to +99 \u030aC<\/li>\n<li>Temperature: -50 to +100 \u030aC<\/li>\n<li>Temperature with T12: -200 to +250 \u030aC<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section id=\"Typical Applications-3\"><strong>Typical Applications<\/strong><\/p>\n<div>\n<ul>\n<li>Climatic chamber validation and calibration<\/li>\n<li>Weather station calibration<\/li>\n<li>RH generator transfer standard<\/li>\n<li>Engine test cells<\/li>\n<\/ul>\n<p><strong>Datasheets<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img decoding=\"async\" class=\"wpdm_icon\" alt=\"Icon\"   src=\"http:\/\/testnordic.com\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.png\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/testnordic.se\/en\/download\/473-dew-point-mirror\/'>473 Dew point mirror<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.62 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a class='wpdm-download-link download-on-click btn btn-primary ' rel='nofollow' href='#' data-downloadurl=\"https:\/\/testnordic.se\/en\/download\/473-dew-point-mirror\/?wpdmdl=3427&refresh=6a5778a0512411784117408\">Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>The 473 is the lowest cost MBW dew point instrument, yet it has similar performance and the same user interface as our high end instruments.<\/p>\n","protected":false},"featured_media":5459,"template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[],"product_cat":[64],"product_tag":[],"yst_prominent_words":[],"class_list":{"0":"post-5458","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-humidity-measurement","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple","13":"entry","14":"content-bg","15":"loop-entry"},"_links":{"self":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product\/5458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product\/5458\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/media\/5459"}],"wp:attachment":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/media?parent=5458"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_brand?post=5458"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_cat?post=5458"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_tag?post=5458"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=5458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}