{"id":4122,"date":"2022-02-25T15:35:01","date_gmt":"2022-02-25T14:35:01","guid":{"rendered":"http:\/\/en.testnordic.com\/?post_type=product&#038;p=4122"},"modified":"2023-12-12T14:18:46","modified_gmt":"2023-12-12T13:18:46","slug":"blu-t-series-2","status":"publish","type":"product","link":"https:\/\/testnordic.se\/en\/product\/blu-t-series-2\/","title":{"rendered":"Battery Capacity Tester \/ Discharge Tester  BLU-T Series"},"content":{"rendered":"<h1>BLU-T Series Battery Load Unit<\/h1>\n<p>The BLU-T Series battery load unit can perform the <strong>battery capacity test<\/strong> on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of <strong>5,25 \u2013 70,5 V DC<\/strong>.<\/p>\n<p>The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11\/22, and other relevant standards.<\/p>\n<p>BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T series battery load units can be connected in parallel, or <a href=\"https:\/\/www.dv-power.com\/product\/extra-load-units\/extra-load-unit-bxl\/\">BXL-T additional load<\/a> units can be linked. The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg \/ 28.2 lbs and up to 19,2 kW of power.<\/p>\n<p>A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.<\/p>\n<p>Discharge parameters of BLU-T series can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with <a href=\"https:\/\/www.dv-power.com\/dv-win-software\/\">DV-B Win software<\/a>. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.<\/p>\n<p>Testing can be carried out without disconnecting the battery from the service.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.dv-power.com\/wp-content\/uploads\/2023\/04\/TBL_WEB_BLU-T_OPT_102-300x209.jpg\" alt=\"BLU-T Discharge Currents Table\" \/><\/p>\n<p><strong>Datasheet<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img decoding=\"async\" class=\"wpdm_icon\" alt=\"Icon\"   src=\"http:\/\/testnordic.com\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.png\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/testnordic.se\/en\/download\/broschure-blu-series-battery-load-units\/'>Broschure BLU-T SERIES Battery Load Units<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 611.71 KB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a class='wpdm-download-link download-on-click btn btn-primary ' rel='nofollow' href='#' data-downloadurl=\"https:\/\/testnordic.se\/en\/download\/broschure-blu-series-battery-load-units\/?wpdmdl=5757&refresh=6a8c18f58d7fb1787566325\">Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<p>&nbsp;<\/p>\n<p><iframe src=\"https:\/\/www.youtube.com\/embed\/nrAs6RHqpBo\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Battery load bank <strong>BLU-T<\/strong> is a powerful and lightweight solution designed for <strong>condition assessment<\/strong> of telecommunication and radio equipment backup supply.<\/p>\n","protected":false},"featured_media":9956,"template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[],"product_cat":[58,90],"product_tag":[],"yst_prominent_words":[],"class_list":{"0":"post-4122","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-battery-test-equipment","7":"product_cat-discharge-testers","9":"first","10":"instock","11":"product-type-simple","12":"entry","13":"content-bg","14":"loop-entry"},"_links":{"self":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product\/4122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product\/4122\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/media\/9956"}],"wp:attachment":[{"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/media?parent=4122"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_brand?post=4122"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_cat?post=4122"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/product_tag?post=4122"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/testnordic.se\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=4122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}